PHYSICAL PARAMETERS
| 1. | Ω - sensing axis, 90°± 0.5° to the reference plane |
| 2. | Dissipation - 1 W |
| 3. | Weight - 150 gram (180 gram max) |
| 4. | Volume - 0.1 litre |
| 5. | Housing material - aluminum alloy |
| 6. | Housing protection - powder coating |
| 7. | Tolerances per ISO 2768-m |
| 8. | Ingress protection class - IP67 |
Specification
MAIN PARAMETERS ( typical values )
| ♦ Rate range | 150 deg/s |
| Scale Factor (SF) | 7 mV/deg/s |
| Frequency range | 0... 0.45 kHz |
| Angle random walk | 0.04 deg /√ h |
| Bias stability, RMS | 2 deg/h |
| SF stability, RMS | 0.1 % |
| Readiness time | 0.1 s |
ENVIRONMENT
| Temperature operating | -40°C ... +70°C |
| Temperature endurance, 2 hr | -55°C... +85°C |
| Vibration, RMS | 18g,20Hz...2kHz |
| Shocks | 450g, 3 ms |
| Acceleration | 5 g |
RELIABILITY
| ♦♦ MTBF | 95000 hours (20º С, predicted) |
| ♦♦ Lifetime (predicted) | 15 years |
| ♦ Precision class - 4 |
| ♦♦ Estimated for low humidity |
RECOMMENDATIONS AND PRECAUTIONS
| 1. | Do not deform housing |
| 2. | Fragile components inside - no shocks, no dro |
| 3. | Treat as electrostatic sensitive unit |
| 4. | Is designed to be mounted inside water protected equipment |
| 5. | Increased humidity shortens essentially lifetime |
| 6. | Mounting surface must be grounded |
| 7. | Power must be off during connecting |
| 8. | Soldering to contacts - by low-temperature solder |