24VDC 800A Magnetic Busbar Con

Click image to view original image
Price: Negotiable
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2017-07-16 00:16
Hits: 80166
Enquiry
Company Detail
 
 
Details
Product DescriptionASW800 12V/24V/36V/48V/60V/72V/84V/120VDC 800A Used For Electric Forklift Trucks Electric Vehicles And Engineering Machinery Bus Bar Connection AOKAI DC ContactorASW800 is a large current contactor with 20,000 ops electric life and 100,000 ops mechanical life. The working duty is continuous working. The mounting bracket is "L" shape. Diode is optional according to client’s demand.FAQ: Q: What does the LVD mean? A: Low Voltage Disconnect.Q: What’s the maximum switched main contact voltage? A: 60VDC without magnetic blowouts / otherwise 96VDC.Q: What are the main contact materials? A: Presently about 10% Cadmium, the rest is silver.Q: What are magnetic blowouts? A: Rare earth magnets molded into the top cover which produce magnetic fields which act on the main contact arcing, thereby extinguishing the arc outwards. This is particularly true in the case of "inductive load".Q: What is the worst type of load to switch? A: Inductive loads first, capacitive loads second, resistive loads are the forgiving loads to switch.Brand: AK/AOKAI Name: DC Contactor Model: ASW800 / SW800 Rated Voltage: DC12V/24V/36V/48V/60V/72V/84V/120V etc.Rated Current: 800A Dimension: 128.5*65.5*150 (mm) Weight: about 1650gSPECIFICATION Coil Rated VoltageDC12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V etc. Main Circuit Rated Current (A)800A Main Circuit Contact Voltage dro (Load:100A) ≤80mV Under (20±5)℃ , Cooling Pull-in Voltage≤70% Under (20±5)℃ , Cooling Drop-out Voltage≥5%, ≤40% Acceptable Fluctuation Range of Coil Voltage±20% Pull-in Time (N/O Contacts to Close)≤30ms Drop-out Time (N/O Contacts to Open)≤20ms The Max Disconnecting Time of Contacts≤5ms Insulation Resistance≥50MΩ Dielectric Strength50Hz/60Hz 1000VAC/1min Overload Current≤7Ie, ≤1s Coil Power Consumption (W)≤15.0W Electrical Life20,000 times Mechanical Life300 Thousand times Working ModeContinuous Contact Form1 NO Contact MaterialAgCdO / AgCuO Auxiliary Contact Rated Load (Optional Parts)2A/48VDC, 5A/24VDC Technical StandardGB14048.4-2010USAGE ENVIRONMENT      Altitude≤2KmAmbient Temperature-25~+55℃International Protection GradeIP50Installation TypeIIIWay to InstallAnyVibration2.5g (5~50)HzImpact50g,11ms (Half-Sine Wave)SCHEMATIC DIAGRAMINSTALLATION DIAGRAMHot Sale ProductsPackaging & ShippingCompany InformationngProduct Application
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]