TML20N-400low pollution reverse osmosis
I. Summary
TML20N-400 low pollution membrane reverse osmosis component, efficient membrane area is 400 square foot, the width of feedwater channel is 34mil. It is suitable for the brackish water and surface water and industrial waste water desalinization of less than 10000 ppm salt content, which is the special use of strict pretreatment system. Because the membrane displays electric neutrality, which can reduce the adsorption of bacteria and microorganisms, the most wide feedwater channel is 34mil, which has the strong anti-pollution, which is more beneficial to the restorement after chemical cleaning.
II. Performance specifications of membrane component
Membrane component modelStandard desalinization rate %Permeable water quantity gpd(m3/d)Effective membrane area ft2(m2)
TML20N-40099.710,200(39)400(37)
Test conditionsOperation pressure225 psi (1.6Mpa)
Test liquid temperature77F()
Test liquid density2000mg/L (as Nacl)
Water recovery rate of membrane component15%
Test liquid PH7
Min. Desalinization rate of single membrane99%
Min. Permeable water quantity is more than or equal to8,200gpd (/d)
The limitation conditions:
Max. Operation pressure600 psi (4.1Mpa)
Max. Feedwater flow70gpm(382 m3/d)
Max. Feedwater temperature113F(45℃)
Max. Feedwater SDI5
Free chlorine density of feed waterNothing for test
Feedwater PH of continuous operation2-11
Feedwater PH of chemical cleaning1-12
Max. Pressure loss of single membrane component20 psi (0.14Mpa)
Single maximum pressure loss membrane module60 psi (0.42Mpa)