Bactericidal effect: 304S.S cylinder using food-grade stainless steel, polished inside and outside the main body to enhance the intensity of ultraviolet radiation, had running water is less than the thickness of 10mm, high-intensity quartz lamps using ultraviolet light, will enable the bactericidal effect of the best. |
||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
![]() |
||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
7Mounting brackets A0506 A0506 Installation Steps 1 Tightening clip into the housing ,the other side of joint connect with pipe water. 2.Fix the Stainless steel housing on mounting brackets ,and then switch on power Maintenance Suggestion To operate the sterilizer properly and attain its maximum efficiency that user need to do some maintenance jobs as below 1.Quartz water sleeve is to be cleaned every 3-6 months, Step is : (1) Cut off power supply (2)Unscrew and remove integration of sterilization lamps, and then remove the sleeve ,at last remove the rubber protection ring and sealing ring from the sleeve (3) With alcohol to clean the surface of the water stain(4)Re-install 2..UV lamp replacement is recommended every 8000 hours of operation. Step is: (1) Cut off power supply (2) Remove the integration of instantaneous sterilization lamps (3) Replacement of a new one ,(4)Re-install 3. To avoid frequent opening and shutting down, so as to extend the service life of UV lamps. |