Boats Pump Parts Types Magneti

Click image to view original image
Price: Negotiable
Min.Order:
Supply
Delivery: Shipment within 3 days since the date of payment
Address: China
Valid until: Never Expire
Updated on: 2017-07-15 22:22
Hits: 60022
Enquiry
Company Detail
 
 
Details
Product Description ADC125-2T 12V/24V/36V/48V/60V/72V/84V/120VDC 125A Used in Elevator Parts Charging Pile Forklift Circuit Winch Relay DC Magnetic Contactor The ADC125-2T has been designed for direct current loads, particularly motors as used on small electric vehicles such as light industrial trucks. Developed for both interrupted and uninterrupted loads, the ADC125-2T is suitable for switching Resistive, Capacitive and Inductive loads. Interrupted current - opening and closing on load with frequent switching (results in increased contact resistance). Uninterrupted current - no or infrequent load switching requirements (maintains a lower contact resistance). The ADC125-2T features double breaking main contacts with silver alloy tips, which are weld resistant, hard wearing and have excellent conductivity. The ADC125-2T is a monoblock construction, resulting in a neat compact design which is compatible with modern electronic control systems. The M8 stud main terminals can be configured in a variety of ways in order to suit the application. Supplied with a mounting bracket as standard, or alternatively supplied with M4 tapped holes. Mounting can be horizontal or vertical, when vertical the M8 contact studs should point upwards. If the requirement is for downwards orientation we can adjust the contactor to compensate for this.Brand: AK/AOKAI Name: DC Reversing Contactor Model: ADC125-2T / DC92 Rated Voltage: DC12V/24V/36V/48V/60V/72V/84V/120V etc.Rated Current: 125A Working Duty: Continuous Dimension: 65.5*97.5*100 (mm) Weight: about 1020gSPECIFICATION  Coil Rated VoltageDC12V, 24V, 36V, 48V, 60V, 72V, 84V, 120V etc. Main Circuit Rated Current (A)125A Main Circuit Contact Voltage dro (Load:100A) ≤80mV Under (20±5)℃ , Cooling Pull-in Voltage≤70% Under (20±5)℃ , Cooling Drop-out Voltage≥5%, ≤40% Acceptable Fluctuation Range of Coil Voltage±20% Pull-in Time (N/O Contacts to Close)≤30ms Drop-out Time (N/O Contacts to Open)≤20ms The Max Disconnecting Time of Contacts≤5ms Insulation Resistance≥50MΩ Dielectric Strength50Hz/60Hz 1000VAC/1min Overload Current≤7Ie, ≤1s Coil Power Consumption (W)≤11.0W Electrical Life20,000 times Mechanical Life300 Thousand times Working ModeContinuous Contact Form2 NO And 2 NC Contact MaterialAgCdO / AgCuO Auxiliary Contact Rated Load (Optional Parts)2A/48VDC, 5A/24VDC Technical StandardGB14048.4-2010USAGE ENVIRONMENT      Altitude≤2KmAmbient Temperature-25~+55℃International Protection GradeIP50Installation TypeIIIWay to InstallAnyVibration2.5g (5~50)HzImpact50g,11ms (Half-Sine Wave)SCHEMATIC DIAGRAMProduct Photo ShowHot Sale ProductsPackaging & ShippingCompany InformationProduct Application
Total: 0 [Show All]  Related Reviews
 
More »Our Others Products

[ ProductsSearch ]  [ Add To Favourite ]  [ Tell Friends ]  [ Print Content ]  [ Violation Report ]  [ Close Window ]